Valeo unveils aluminum rear-door cooling module for data centers, claiming 38% more cooling than copper

Valeo is taking its automotive thermal engineering into the data center, unveiling an aluminum rear-door cooling module it says delivers 38% more cooling capacity and 65% higher power density than copper equivalents.

Cooling capacity gain vs copper equivalents
38%
Power density increase vs copper equivalents
65%
Heat flux handled by Valeo cold plates
200 W/cm²
Share of AI servers still air cooled
47%

What Happened

Valeo will give visitors a first hands-on look at its aluminum Rear Door Cooling Module (RDHx) at Data Centre World (Tech Show Paris), running November 18 to 19, 2026 at Booth M100, Hall 5, Paris Expo Porte de Versailles. The module is shown alongside a complete lineup of thermal management solutions. Valeo says it is drawing on decades of automotive thermal engineering and high-volume manufacturing expertise to bring automotive-grade reliability and industrial scalability to modern digital infrastructure.

Aluminum RDHx vs conventional copper equivalents
Cooling capacity
+38%
Power density
+65%
Electrical fan consumption
-25%

For direct-to-chip cooling, Valeo is displaying single-phase and two-phase Cold Plates designed for CPUs and GPUs. A multi-material architecture with a secure, no-seal casing saddle assembly process minimizes copper use for a lighter footprint while maximizing leak resistance, and the internal heat-exchange design dissipates heat fluxes reaching up to 200 W/cm² while optimizing pump mass flow. Complementing the cold plates are Cooling Distribution Units (CDUs) and manifolds for single- or two-phase applications, built to automotive quality standards for continuous, zero-failure operation. They feature hot-swappable pumps, brazed junctions, failure prediction controls and predictive maintenance software.

What Valeo is showing at Booth M100
  • Aluminum Rear Door Cooling Module (RDHx), engineered for high-density racks and fan wall applications across multiple rack sizes
  • Single-phase and two-phase Direct-to-Chip Cold Plates for CPUs and GPUs
  • Cooling Distribution Units (CDUs) and rack manifolds for single- or two-phase use
  • Passive two-phase Direct-to-Chip loop heat pipe system at server level, co-developed with Calyos
AI servers that are air cooled today

47%

Valeo says even best-in-class air-cooled servers cannot run today's top GPUs at full power.

Valeo is also demonstrating a passive two-phase Direct-to-Chip cooling system at server level powered by Loop Heat Pipe (LHP) technology, co-developed in partnership with Calyos. Rather than mechanical liquid pumps, it uses capillary and gravity action. Valeo says the two-phase fluid delivers 27% higher cooling capacity versus air and cuts fan consumption by 40%. The system is pitched at air-cooled CPU racks used for inference tasks and as a smart autonomous cooling solution for edge compute applications.

“We are proud to present our aluminum heat exchanger cooling module technology for the first time at Data Centre World Paris. Data centers today are caught between increasing AI compute densities and strict energy targets. Whether facilities are looking to upgrade existing racks or architect next-generation AI clusters from the ground up, Valeo offers a large portfolio of practical, scalable tools to cut power usage and sustainably while maximizing compute capacity.”
— Pascale Herman, Data Centers & BESS Vice President at Valeo

Why this matters

AI workloads are pushing individual chip thermal design power past what air cooling can handle, so data center operators face an urgent need to move to liquid cooling and cut energy use. Valeo is pitching automotive-grade reliability and high-volume manufacturing at both new builds and retrofits of existing racks, putting an automotive supplier into digital infrastructure.

Terms in This Story

TDP (Thermal Design Power)
A measure of the maximum heat a processor is expected to give off under normal operation, used to size the cooling it needs.
PUE (Power Usage Effectiveness)
The ratio of a data center's total power use to the power delivered to its computing equipment; closer to 1 means less energy lost to overheads such as cooling.
Direct-to-Chip (DtC) cooling
A liquid cooling approach in which coolant is piped to cold plates mounted directly on processors to carry heat away.
Two-phase cooling
A cooling method in which a fluid absorbs heat by boiling into vapour and releases it by condensing back into liquid.